Description

Circuit Description
This fault code checks for system errors in the aftertreatment fuel injection system. This diagnostic can detect malfunctions of the aftertreatment fuel shutoff valve.

Before active regeneration of the aftertreatment diesel particulate filter, a diagnostic test on the system is performed. The aftertreatment fuel injector opens and relieves fuel pressure in the line. The aftertreatment fuel pressure sensor must be reading atmospheric pressure at this point in the test. The aftertreatment fuel injector closes and the aftertreatment purge air actuator opens. This pressurizes the aftertreatment fuel system to vehicle air pressure. The diagnostic then checks to make sure the aftertreatment fuel pressure sensor is reading vehicle air pressure. The aftertreatment fuel shutoff valve then opens and allows pressurized fuel to enter the system. The aftertreatment fuel injector then opens and primes the system by purging the air from the line. The aftertreatment fuel shutoff valve and aftertreatment fuel injector then close and trap the fuel between the aftertreatment fuel shutoff valve and the aftertreatment fuel injector. The diagnostic checks to make sure the system maintains fuel pressure.

Component Location
The aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.

Conditions for Running the Diagnostics
This diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault Codes
The engine control module (ECM) detected an internally leaking aftertreatment fuel shutoff valve, aftertreatment purge air actuator, or a stuck closed aftertreatment fuel injector.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
Active regeneration of the aftertreatment diesel particulate filter will be disabled until the next key cycle.
Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code
To validate the repair, perform INSITE? electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test. Once the temperatures in the aftertreatment are warm enough to inject diesel fuel into the exhaust, the diagnostic will run.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.
For On-Board Diagnostics (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.
The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications

Shop Talk
Possible causes of this fault code include:

Internal leak of the aftertreatment fuel shutoff valve allowing fuel pressure to leak past the shutoff valve.

Possible Cause:
1) Aftertreatment fuel Pressure Sensor failure
2) Aftertreatment Injector
3) ECM calibration

Related

Tags: 1-, 1925, 2, 2010-12, 334, 3482, Aftertreatment, CM2250, Code, Cummins, Data, Erratic, Fault, FMI, Fuel, Incorrect, Intermittent, ISX15, or, PID, Shutoff, SID, SPN, Valve

Reviews

There are no reviews yet.

Be the first to review “Cummins ISX15 CM2250 (2010-12) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1- Data Erratic, Intermittent, or Incorrect”

Categories Cumminz, DTC TRUCKS, ISX15 CM2250 (2010-12)Tags 1-, 1925, 2, 2010-12, 334, 3482, Aftertreatment, CM2250, Code, Cummins, Data, Erratic, Fault, FMI, Fuel, Incorrect, Intermittent, ISX15, or, PID, Shutoff, SID, SPN, Valve

  • Related Products

Quick View

Add to wishlist

CompareAdd to cart

AllisonDTC TRUCKS

Quick View

Add to wishlist

CompareAdd to cart

AllisonDTC TRUCKS

Quick View

Add to wishlist

CompareAdd to cart

AllisonDTC TRUCKS

Quick View

Add to wishlist

CompareAdd to cart

AllisonDTC TRUCKS

Quick View

Add to wishlist

CompareAdd to cart

AllisonDTC TRUCKS

  • JPRO

    DOWNLOAD Noregon JPRO Commercial Fleet Diagnostics 2017 v3 (Copy)

    $40.00Add to cart

  • cummisznn

    Cumminmms Insite pro 8.9 Diagnostic Software

    $80.00Add to cart

  • Trucks software

    JPRO Diagnostic Software Download 2024

    $100.00Add to cart

  • Trucks software

    AGCO EDT 2023.10 Electronic Diagnostic Tool 1.125

    $120.00Add to cart

  • Trucks software

    DOOSAN diagnostic software DMS-5 3.1.3 [2023.11] 1PC

    $106.00Add to cart

  • Trucks software

    Bendix Acom Pro 2023 V1 diagnostic software 1PC

    $83.00Add to cart

  • Trucks software

    VOLVOUU PTT TECH TOOL 2.8.220 2023 Last version 1pc

    $200.00Add to cart

  • Trucks software

    Download Allison Doc Premium Update 2023 v2

    $105.00Add to cart

  • Allison

    SERVICE MANUAL 5000, 6000, 8000, 9000 SeriesOff-Highway Transmissions Commercial Electronic Controls 2 (CEC2) TS3353EN Troubleshooting Manual PDF.pdf

    $45.00Add to cart

  • EATON

    SERVICE MANUAL EATON UltraShift PLUS

    $45.00Add to cart

  • CAT

    DOWNLOAD Cat Factory Password Generator 1.0 2019 WINDOWS 10

    $56.00Add to cart

  • FUSO

    $45.00Add to cart

  • Trucks software

    Diesel Diagnostic Link 8.17 SP1 2023

    $96.00Add to cart

  • Trucks software

    DOWNLOAD VOLVOUU MATRIS 2.3.3

    $65.00Add to cart

  • Thermo King

    DOWNLOAD Thermo King EPC 2012

    $45.00Add to cart

  • Trucks software

    DOWNLOAD Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software

    $86.00Add to cart

Cummins ISX15 CM2250 (2010-12) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1- Data Erratic, Intermittent, or Incorrect - dtctruck (2024)
Top Articles
Latest Posts
Article information

Author: Jerrold Considine

Last Updated:

Views: 5471

Rating: 4.8 / 5 (58 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Jerrold Considine

Birthday: 1993-11-03

Address: Suite 447 3463 Marybelle Circles, New Marlin, AL 20765

Phone: +5816749283868

Job: Sales Executive

Hobby: Air sports, Sand art, Electronics, LARPing, Baseball, Book restoration, Puzzles

Introduction: My name is Jerrold Considine, I am a combative, cheerful, encouraging, happy, enthusiastic, funny, kind person who loves writing and wants to share my knowledge and understanding with you.